| Name | Indication | Color | Status | Explanation |
|---|---|---|---|---|
| RUN | Run | Green | OFF | State INIT or Power OFF |
| Blinking | State PRE-OPERATIONAL | |||
| Single Flash | State SAFE-OPERATIONAL | |||
| ON | State OPERATIONAL | |||
| Flickering | State BOOTSTRAP | |||
| Error | ERR | Red | OFF | No Error or Power OFF |
| Blinking | Invalid Configuration | |||
| Single Flash | Local Error | |||
| Double Flash | Watchdog Time Out | |||
| Link / Activity |
LA1 LA2 |
Green | OFF | Link not Established |
| ON | Link Established | |||
| Flickering | Link Established and in Operation |

| Indication | Color | Function | ON/OFF Condition |
|---|---|---|---|
| PWR | Green | Power input indication | LED is turned ON when power is applied |
| RUN | Yellow | Motor running indication | LED is turned ON while motor is rotating |
| SON | Orange | STEP On / Off Indication | STEP On: Lights On, STEP Off: Lights Off |
| ALM | Red | Alarm Indication | Flash when protection function is activated(Identifiable which protection mode is activated by counting the blinking times) |

| Times | Protection | Conditions |
|---|---|---|
| 1 | Over Current Error | The current through power devices in inverter exceeds 4.8A |
| 2 | Over Speed Error | Motor speed exceeds 3,000 [rpm] |
| 5 | Over Temperature Error | Inside temperature of drive exceeds 85℃ |
| 6 | Over Regenerated Voltage Error | Back-EMF more than 48V |
| 7 | Motor Connection Error | The drive does STEP ON without connection of the motor cable to drive |
| 9 | Motor Power Error | The input voltage of the motor power is too low or disconnected |
| 12 | ROM Error | Error occurs in parameter storage device(ROM) |

| NO. | Function | I/O |
|---|---|---|
| 1 | EXT_24VDC | Input |
| 2 | EXT_GND | Input |
| 3 | LIMIT+ | Input |
| 4 | LIMIT- | Input |
| 5 | ORIGIN | Input |
| 6 | BRAKE+ | Output |
| 7 | BRAKE- | Output |

| NO. | Function | I/O |
|---|---|---|
| 1 | A+ | Input |
| 2 | A- | Input |
| 3 | B+ | Input |
| 4 | B- | Input |
| 5 | Z+ | Input |
| 6 | Z- | Input |
| 7 | 5VDC | Output |
| 8 | GND | Output |
| 9 | F.GND | ---- |
| 10 | F.GND | ---- |

| NO. | Function | I/O |
|---|---|---|
| 1 | A Phase | Output |
| 2 | B Phase | Output |
| 3 | / A Phase | Output |
| 4 | / B Phase | Output |

| NO. | Function | I/O |
|---|---|---|
| 1 | 24VDC | Input |
| 2 | GND | Input |

| NO. | Function | I/O |
|---|---|---|
| 1 | 24VDC | Input |
| 2 | 24VDC | Input |
| 3 | 24VDC | Input |
| 4 | F.GND | ---- |
| 5 | GND | Input |
| 6 | GND | Input |
| 7 | GND | Input |
| 8 | F.GND | ---- |

| NO. | Function |
|---|---|
| 1 | TD+ |
| 2 | TD- |
| 3 | RD+ |
| 4 | ---- |
| 5 | ---- |
| NO. | Function |
|---|---|
| 6 | RD- |
| 7 | ---- |
| 8 | ---- |
| Connection Hood |
F.GND |

| NO. | Function |
|---|---|
| 1 | VBUS |
| 2 | D- |
| 3 | D+ |
| 4 | ---- |
| 5 | GND |

Connector Specifications
| Purpose | Item | Part Number | Manufacturer | |
|---|---|---|---|---|
| Main Power (CN5) |
Housing Terminal |
5557-08R 5556T |
MOLEX | |
| Control Power (CN4) |
Housing Terminal |
5557-02R 5556T |
MOLEX | |
| Motor | Drive Side (CN3) |
Housing Terminal |
5557-04R 5556T |
MOLEX |
| Motor Side | Housing Terminal |
5557-04R 5556T |
MOLEX | |
| Encoder | Drive Side (CN2) |
Housing Terminal |
51353-1000 56134-9000 |
MOLEX |
| Signal (CN1) |
Housing Terminal |
PAP-07V-S SPHD-001T-P0.5 |
JST | |