| Indication | Color | Function | ON/OFF Condition |
|---|---|---|---|
| PWR | Green | Power Input Indication | Lights when power is ON Flashs when motor is Free status |
| ALM | Red | Alarm Indication | Flash when protection function is activated (Identifiable which protection mode is activated by counting the blinking times) |
| CW | Yellow | Motor Rotation Direction | Lights when motor rotate CW direction |
| CCW | Orange | Motor Rotation Direction | Lights when motor rotate CCW direction |
| Times | Protection | Conditions |
|---|---|---|
| 1 | Over Current Error | The current through power devices in drive exceeds the limit value*1 |
| 2 | Over Speed Error | Motor speed exceed 3,000 [rpm] |
| 3 | Step Out Error | Abnormally motor do not followed pulsed input |
| 5 | Over Temperature Error | Inside temperature of drive exceeds 85℃ |
| 6 | Over Regenerated Voltage Error | Back-EMF more high limit value*2 |
| 7 | Motor Connection Error | The power is ON without connection of the motor cable to drive |
| 9 | Motor Voltage Error | Motor voltage is out of limited value*3 |
| 11 | System Error | Error occurs in drive system |
| 12 | ROM Error | Error occurs in parameter storage device(ROM) |

| Position | ID Number |
|---|---|
| 0 | 0 |
| 1 | 1 |
| 2 | 2 |
| 3 | 3 |
| 4 | 4 |
| 5 | 5 |
| 6 | 6 |
| 7 | 7 |
| Position | ID Number |
|---|---|
| 8 | 8 |
| 9 | 9 |
| A | 10 |
| B | 11 |
| C | 12 |
| D | 13 |
| E | 14 |
| F | 15 |

| SW2.1 | SW2.2 | SW2.3 | SW2.4 | Baud Rate [bps] |
|---|---|---|---|---|
| - | OFF | OFF | OFF | 9,600 |
| - | ON | OFF | OFF | 19,200 |
| - | OFF | ON | OFF | 38,400 |
| - | ON | ON | OFF | 57,600 |
| - | OFF | OFF | ON | 115,200*1 |
| - | ON | OFF | ON | 230,400 |
| - | OFF | ON | ON | 460,800 |
| - | ON | ON | ON | 921,600 |
| No. | Function | I/O |
|---|---|---|
| 1 | LIMIT+ | Input |
| 2 | LIMIT- | Input |
| 3 | ORIGIN | Input |
| 4 | Digital In1 | Input |
| 5 | Digital In6 | Input |
| 6 | Digital In7 | Input |
| 7 | Compare Out | Output |
| 8 | Digital Out1 | Output |
| 9 | Digital Out2 | Output |
| 10 | Digital Out3 | Output |
| 11 | Digital Out4 | Output |
| 12 | Digital Out5 | Output |
| 13 | Digital Out6 | Output |
| No. | Function | I/O |
|---|---|---|
| 14 | Digital In2 | Input |
| 15 | Digital In3 | Input |
| 16 | Digital In4 | Input |
| 17 | Digital In5 | Input |
| 18 | Digital In8 | Input |
| 19 | Digital In9 | Input |
| 20 | Digital Out7 | Output |
| 21 | Digital Out8 | Output |
| 22 | Digital Out9 | Output |
| 23 | BRAKE+ | Output |
| 24 | BRAKE- | Output |
| 25 | EXT_GND | Input |
| 26 | EXT_24VDC | Input |

| No. | Function | I/O |
|---|---|---|
| 1 | A+ | Input |
| 2 | A- | Input |
| 3 | B+ | Input |
| 4 | B- | Input |
| 5 | Z+ | Input |
| No. | Function | I/O |
|---|---|---|
| 6 | Z- | Input |
| 7 | 5VDC | Output |
| 8 | GND | Output |
| 9 | F.GND | --- |
| 10 | F.GND | --- |

| No. | Function | I/O |
|---|---|---|
| 1 | A Phase | Output |
| 2 | B Phase | Output |
| 3 | / A Phase | Output |
| 4 | / B Phase | Output |

| No. | Function | I/O |
|---|---|---|
| 1 | / B Phase | Output |
| 2 | B Phase | Output |
| 3 | / A Phase | Output |
| 4 | A Phase | Output |
※ Only for 86mm motor drive.

| No. | Function | I/O |
|---|---|---|
| 1 | 24VDC | Input |
| 2 | GND | Input |

| No. | Function | I/O |
|---|---|---|
| 1 | GND | Input |
| 2 | 40~70VDC | Input |
※ Only for 86mm motor drive.

| No. | Function |
|---|---|
| 1 | GND |
| 2 | GND |
| 3 | Data+ |
| 4 | GND |
| 5 | GND |
| No. | Function |
|---|---|
| 6 | Data- |
| 7 | GND |
| 8 | GND |
| LED 1, 3 | Drive status |
| LED 2, 4 | Communication status |

Connector Specifications
| Purpose | Item | Part Number | Manufacture | |
|---|---|---|---|---|
| Power (CN4) |
Housing Terminal |
5557-05R 556T |
MOLEX | |
| Motor | Drive Side (CN2) |
Housing Terminal |
5557-04R 556T |
MOLEX |
| Motor Side | Housing Terminal |
5557-04R 556T |
MOLEX | |
| Encoder | Drive Side (CN2) |
Housing Terminal |
51353-1000 56134-9000 |
MOLEX |
| Signal (CN1) |
Connector Backshell |
10126-3000PE 10326-52F0-008 |
3M | |