Ezi-IO Plus-E

Ezi-IO-PE-■16□-E / Ezi-IO-PE-I8O8□-E Series

Settings and Operation



Status LED

1. Status LED
Indication Color Function ON/OFF Condition
PWR Red Power input indication Turn on when power is applied
RUN Green Display module status Flashing when normal operation
Link1, 2 Green Link Status Turn on when Link is activated
ACT1, 2 Yellow Activity Status Flashing when communicating
0~15
0~7/0~7
Green I/O status indication Input Module : Turn on when input signal is ON
Output Module : Turn on when output signal is ON

Switch

1. Ethernet IP Display and Setting Switch(SW1, SW2)
It can be set the value of the fourth digit of Ethernet IP through the setting switch. Set the product’s IP not to overlap with the connected products. The first, second and third values of IP can be set through the GUI. Please refer to the manual for details. When the switch is set to 255 (FF), IP is automatically set, ignoring the setting. (DHCP function).
Example) in case SW2=5, SW1=7
     5×16 + 7×1 = 87
     therefore, IP 192.168.0.87

Connector

1. Power Connector(CN1)
NO. Function I/O
1 24VDC Input
2 GND Input
*Be sure to supply power which is suitable for the load of I/O and control.
2. I/O Connector(CN2)
NO. Function I/O
1 24VDC Output
2 NC ----
3 GND Output
4 SIGNAL I/O
3. Ethernet Communication Connector(CN3, CN4)
NO. Function
1 TD+
2 TD-
3 RD+
4 ----
5 ----
NO. Function
6 RD-
7 ----
8 ----
Connector
hood
F.GND

Connector Specifications

Connector specifications for cabling to module.
Purpose Item Part Number Manufacturer
Power(CN2) Terminal Block MC421-38102 DECA
I/O(CN1) e-CON Plug Connector CNE-P04-YW Autonics
※ Above connector is the most suitable product for the module applied. Another equivalent connector can be used.

Ezi-IO-PE-■16□-T / Ezi-IO-PE-I8O8□-T Series

Settings and Operation



Status LED

1. Status LED
Indication Color Function ON/OFF Condition
PWR Red Power input indication Turn on when power is applied
RUN Green Display module status Flashing when normal operation
Link1, 2 Green Link Status Turn on when Link is activated
ACT1, 2 Yellow Activity Status Flashing when communicating
0~15
0~7/0~7
Green I/O status indication Input Module : Turn on when input signal is ON
Output Module : Turn on when output signal is ON

Switch

1. Ethernet IP Display and Setting Switch(SW1, SW2)
It can be set the value of the fourth digit of Ethernet IP through the setting switch. Set the product’s IP not to overlap with the connected products. The first, second and third values of IP can be set through the GUI. Please refer to the manual for details. When the switch is set to 255 (FF), IP is automatically set, ignoring the setting. (DHCP function).
Example) in case SW2=5, SW1=7
     5×16 + 7×1 = 87
     therefore, IP 192.168.0.87

Connector

1. Power Connector(CN1)
NO. Function I/O
1 24VDC Input
2 GND Input
*Be sure to supply power which is suitable for the load of I/O and control.
2. I/O Connector(CN1)
NO. Function I/O
1 24VDC Output
2 24VDC Output
3 SIGNAL I/O
4 SIGNAL I/O
5 SIGNAL I/O
6 SIGNAL I/O
7 SIGNAL I/O
8 SIGNAL I/O
9 SIGNAL I/O
10 SIGNAL I/O
11 GND Output
12 GND Output
NO. Function I/O
1 24VDC Output
2 24VDC Output
3 SIGNAL I/O
4 SIGNAL I/O
5 SIGNAL I/O
6 SIGNAL I/O
7 SIGNAL I/O
8 SIGNAL I/O
9 SIGNAL I/O
10 SIGNAL I/O
11 GND Output
12 GND Output
3. Ethernet Communication Connector(CN3)
NO. Function
1 TD+
2 TD-
3 RD+
4 ----
5 ----
NO. Function
6 RD-
7 ----
8 ----
Connector
hood
F.GND

Connector Specifications

Connector specifications for cabling to module.
Purpose Item Part Number Manufacturer
Power(CN2) Terminal Block MC421-38102 DECA
※ Above connector is the most suitable product for the module applied. Another equivalent connector can be used.

Ezi-IO-PE-■32□-E / Ezi-IO-PE-I16O16□-E Series

Settings and Operation



Status LED

1. Status LED
Indication Color Function ON/OFF Condition
PWR Red Power input indication Turn on when power is applied
RUN Green Display module status Flashing when normal operation
Link1, 2 Green Link Status Turn on when Link is activated
ACT1, 2 Yellow Activity Status Flashing when communicating
0~31
0~15/0~15
Green I/O status indication Input Module : Turn on when input signal is ON
Output Module : Turn on when output signal is ON

Switch

1. Ethernet IP Display and Setting Switch(SW1, SW2)
It can be set the value of the fourth digit of Ethernet IP through the setting switch. Set the product’s IP not to overlap with the connected products. The first, second and third values of IP can be set through the GUI. Please refer to the manual for details. When the switch is set to 255 (FF), IP is automatically set, ignoring the setting. (DHCP function)
Example) in case SW2=5, SW1=7
     5×16 + 7×1 = 87
     therefore, IP 192.168.0.87

Connector

1. Control Power Connector(CN1)
NO. Function I/O
1 24VDC Input
2 GND Input
2. I/O Connector(CN2)
NO. Function I/O
1 EXT_24VDC Output
2 NC ----
3 EXT_GND Output
4 SIGNAL I/O
3. Ethernet Communication Connector(CN3)
NO. Function
1 TD+
2 TD-
3 RD+
4 ----
5 ----
NO. Function
6 RD-
7 ----
8 ----
Connector
hood
F.GND
4. I/O Power Connector(CN5)
NO. Function I/O
1 EXT_24VDC Input
2 EXT_24VDC Input
3 EXT_GND Input
4 EXT_GND Input
*Be sure to supply a power source which is suitable for the load of I/O.

Connector Specifications

Connector specifications for cabling to module.
Purpose Item Part Number Manufacturer
Control Power(CN1) Terminal Block MC421-38102 DECA
I/O Power(CN5) Terminal Block MC421-38104 DECA
I/O(CN2) e-CON Plug Connector CNE-P04-YW Autonics
※ Above connector is the most suitable product for the module applied. Another equivalent connector can be used.

Ezi-IO-PE-■32□-T / Ezi-IO-PE-I16O16□-T Series

Settings and Operation



Status LED

1. Status LED
Indication Color Function ON/OFF Condition
PWR Red Power input indication Turn on when power is applied
RUN Green Display module status Flashing when normal operation
Link1, 2 Green Link Status Turn on when Link is activated
ACT1, 2 Yellow Activity Status Flashing when communicating
0~31
0~15/0~15
Green I/O status indication Input Module : Turn on when input signal is ON
Output Module : Turn on when output signal is ON

Switch

1. Ethernet IP Display and Setting Switch(SW1, SW2)
It can be set the value of the fourth digit of Ethernet IP through the setting switch. Set the product’s IP not to overlap with the connected products. The first, second and third values of IP can be set through the GUI. Please refer to the manual for details. When the switch is set to 255 (FF), IP is automatically set, ignoring the setting. (DHCP function)
Example) in case SW2=5, SW1=7
     5×16 + 7×1 = 87
     therefore, IP 192.168.0.87

Connector

1. Control Power Connector(CN1)
NO. Function I/O
1 24VDC Input
2 GND Input
2. I/O Connector(CN1)
NO. Function I/O
1 EXT_24VDC Output
2 EXT_24VDC Output
3 SIGNAL I/O
4 SIGNAL I/O
5 SIGNAL I/O
6 SIGNAL I/O
7 SIGNAL I/O
8 SIGNAL I/O
9 SIGNAL I/O
10 SIGNAL I/O
11 EXT_GND Output
12 EXT_GND Output
NO. Function I/O
1 EXT_24VDC Output
2 EXT_24VDC Output
3 SIGNAL I/O
4 SIGNAL I/O
5 SIGNAL I/O
6 SIGNAL I/O
7 SIGNAL I/O
8 SIGNAL I/O
9 SIGNAL I/O
10 SIGNAL I/O
11 EXT_GND Output
12 EXT_GND Output
3. Ethernet Communication Connector(CN3)
NO. Function
1 TD+
2 TD-
3 RD+
4 ----
5 ----
NO. Function
6 RD-
7 ----
8 ----
Connector
hood
F.GND
4. I/O Power Connector(CN5)
NO. Function I/O
1 EXT_24VDC Input
2 EXT_24VDC Input
3 EXT_GND Input
4 EXT_GND Input
*Be sure to supply a power source which is suitable for the load of I/O.

Connector Specifications

Connector specifications for cabling to module.
Purpose Item Part Number Manufacturer
Control Power(CN1) Terminal Block MC421-38102 DECA
I/O Power(CN5) Terminal Block MC421-38104 DECA
※ Above connector is the most suitable product for the module applied. Another equivalent connector can be used.